发布需求
请登录 注册
鼠爪肿胀测量仪
  • YY-146
  • 玉研仪器
  • 上海市
  • 现货
  • 按需定制
  • 议价
  • 2023-01-05 14:30:06

上海玉研科学仪器有限公司

一键申请试用
咨询
加入意向单
联系方式

肢体肿胀测量仪可用于风湿关节炎、水肿等多种药理实验,精确测量大鼠、小鼠的肢体肿胀情况。自上世纪60年代起,已经有超过1000篇的引用文献。


 


该仪器是大鼠、小鼠炎症、水肿测量的理想工具,测量分辨率是0.01ml。















完整的足趾肿胀测试系统(注:水杯样式有变化)


型号:37140















液晶屏可实时显示实验数据,可将数据导入电脑,进行记录和分析



















大鼠测试杯特写













不同型号的测试水杯

 




特征



优点



脚踏开关用于记录测试数据



免手工操作,更加便利



超过1000引用文献



绝大多数的应用都可以在引用文献中查到



多种尺寸的测量水杯可选        



用于不同体重的大鼠、小鼠实验


 


产品规格:




测量水杯直径



1.3cm (小鼠)



1.8cm,2.5cm,3.5cm (大鼠)



测试精度



0.01ml



数据连接



串行接口或USB接口



软件



标配测试和分析软件



规格重量:



 



重:



4.8Kg



规格尺寸:



67*42*53cm





 









 


大鼠、小鼠完整的测试系统



参考文献:



Phytochemical compounds involved in the anti-inflammatory effect of propolis extract



F Borrelli, P Maffia, L Pinto, A Ianaro, A Russo… - Fitoterapia, 2002 - Elsevier



… The volume of the paw was measured by plethysmometer (Ugo Basile, Milan, Italy) immediately

after the injection … The paw volume was determined by plethysmometer (Ugo Basile, Milan, Italy)

immediately after immunisation and every 7 days for a period of 35 days …



 



Involvement of capsaicin-sensitive neurones in hyperalgesia and enhanced opioid antinociception in inflammation


L Bartho, C Stein, A Herz - Naunyn-Schmiedeberg's archives of …, 1990 - Springer

… cm. Paw volume was measured by means of an Ugo Basile plethysmometer. In some animals a simplified open-field test was carried out in a barriered,diffusely-illuminated area of 70 x 95 cm, divided to 4 x 5 equal squares …


Comparison between plethysmometer and micrometer methods to measure acute paw oedema for screening anti-inflammatory activity in mice



JN Sharma, AM Samud, MZ Asmawi - Inflammopharmacology, 2004 - Springer



… For this assessment, 42 mice that were divided into 6 groups of 7 mice, were used. In these groups,

the measurement of the paw swelling was performed using a volume displacement

plethysmometer (Ugo Basile, Italy) 1 h before induction of oedema and 3.5 h after treatment …


Assessment of the anti-inflammatory activity and free radical scavenger activity of tiliroside



A Sala, MC Recio, GR Schinella, S Máñez… - European Journal of …, 2003 - Elsevier



… Products and reference drug were dissolved in Tween 80–ethanol–saline (1:1:10). Oedema was

measured with a plethysmometer (Ugo Basile) 30, 60 and 90 min after challenge and is expressed

as the difference between the volume of the right and left paws …



 














     




    